| Properties |
Marmox
|
Wedi
|
Aquapanel Thermal
|
Fastwarm®-Xtra
|
| Thermal Conductivity (W/mK) |
0.027
|
0.033
|
0.027
|
0.029
|
| Compressive Strength (kPa) |
300
|
250
|
220
|
300
|
| Water Absorption (Capillarity) |
Nil
|
Nil
|
Nil
|
Nil
|
| Properties |
Celotex GA3000Z
|
Kingspan TF70
|
FloorTherm
|
Fastwarm®
|
| Thermal Conductivity (W/mK) |
0.023
|
0.023
|
0.023
|
0.027
|
| Compressive Strength (kPa) |
120
|
140
|
150
|
300
|
| Water Absorption (Capillarity) |
Nil
|
Nil
|
Nil
|
Nil
|
| Fastwarm®-Xtra Board Sizes | Thermal Conductivity (W/mK) 90 days @ 10°C |
Resistance (K-Value m2) | U-Value (W/m2K) | Compressive Strength (kPa) 1 kPa = 1 kg/cm2 |
Weight (kgs) |
| 1250 x 600 x 6mm | 0.029 | 0.20 | 4.80 | 300 | 1.6 |
| 1250 x 600 x 10mm | 0.029 | 0.34 | 2.90 | 300 | 1.8 |
| Standard | ISO 8301/BS EN 12667 | BS EN 826 |
| Fastwarm® Board Sizes | Thermal Conductivity (W/mK) 90 days @ 10°C |
Resistance (K-Value m2) | U-Value (W/m2K) | Compressive Strength (kPa) 1 kPa = 1 kg/cm2 |
Weight (kgs) |
| 1200 x 600 x 6mm | 0.027 | 0.22 | 4.50 | 300 | 0.13 |
| 1200 x 600 x 10mm | 0.027 | 0.37 | 2.70 | 300 | 0.22 |
| 1250 x 600 x 20mm | 0.029 | 0.69 | 1.45 | 280 | 0.45 |
| 1250 x 600 x 30mm | 0.029 | 1.03 | 0.97 | 280 | 0.68 |
| 1250 x 600 x 40mm | 0.029 | 1.38 | 0.72 | 280 | 0.90 |
| 1250 x 600 x 50mm | 0.029 | 1.72 | 0.58 | 280 | 1.13 |
| 1250 x 600 x 60mm | 0.029 | 2.07 | 0.48 | 280 | 1.35 |
| 1250 x 600 x 80mm | 0.029 | 2.76 | 0.36 | 280 | 1.80 |
| Standard | ISO 8301/BS EN 12667 | BS EN 826 |
Thermal energy moves from a higher temperature to a lower one, the bigger the difference the faster the transfer.
|
Thermal Conductivity |
Measure of the rate at which material will pass heat energy, expressed in units of watts per square metre per degree Celsius of temperature difference (W/mK). |
|
Resistance |
Each type of material has it's own particular rate of thermal conductivity affecting the speed of thermal transfer (K-Value) |
|
U Value |
Measure of how much heat energy will pass through a square metre of structure when air temperatures on either side differ by one degree Celsius. The fabric of any building will typically consists of a number of components each with their characteristic resistance value, the U-Value is a combination of all these values. U-Values are expressed in units of watts per square metre per degree of temperature difference (W/m2K) |
| Properties | Standard | Unit | Data |
| Density | EN 1602 | Kg/m2 | 28 |
| Thermal conductivity, 90 days, 10ºC | ISO 8301 | W/mK | 0.027 |
| Compressive strength at 10% deflection or yield, (vertical) | EN 826 | kPa | 300 |
| Compressive modulus | EN 826 | kN/m2 | 12-20,000 |
| Tensile strength | EN 1607 | kPa | 500 |
| Tensile modulus | EN 1607 | kPa | 12-20,000 |
| Shear strength | EN 1209 | kPa | 250 |
| Shear modulus | EN 1209 | kPa | 8,000 |
| Design compressive stress, <2% compression | EN 1606 | kN/m2 | 110 |
| Water vapour resistivity | EN 12086 | (Uu)- value | 100-160 |
| Water absorption by immersion (28 days, full boards) | DIN 53434 | Vol-% | 0.5 |
| Capillarity | - | nil | nil |
| Coefficient of linear thermal expansion | BS 3837: Method 13 | mm/mK | 0.07 |
| Temperature limits | - | °C | -50/+75 |
| Fire classification | Bs 3837: Pt2: 1990 |
- | - |
| Edge profile | - | - | butt |
| Surface finish | - | - | planed |
Please note: All our prices are inclusive of VAT
All major Credit Cards are accepted in our online shop
Floor Heating Ltd - providing heat at your feet